VeratNet
VeratNet Data Center, Serbia
Basic facts
VeratNet's Data Center is one of the most modern facilities of this kind in the country. It is projected according to modern trends of ANSI-TIA standards for facilities of this kind, and is situated within the VeratNet's commercial building in 37 Vojvode Misica Boulevard.
. Guaranteed redundancy of all systems (UPS equipment, air conditioning, network wiring)
. High quality components
. Reliability and availability of 99.999%
. 55 cm high floor
. Local redundant cabling and floor cooling located below the floor
. Optimal temperature for equipment functioning
. Internal cabling with redundant fiber optic cables
. Users connected to all international Internet links available in the country
. Equipment located in 42U racks
. Highly sophisticated system of surveillance
. 24 / 7 video surveillance system with restrictive access control
. Modern fire detection system
. Senior level administrators are always available for the highest possible level of support
Electricity supply
. The system secured with 2 +1 redundancy (MGE Galaxy 5000 100kVA UPS)
. 400 kVA Caterpillar diesel - started automatically in case of power cuts
. Uninterruptible power supply and a minimum possibility of power failure
Access Control and Video Surveillance
We provide you with the highest level of security to your equipment, 24 hours a day. With multiple levels of security, entering the data center is controlled by proximity cards and access codes.
. No public access to the data center is available
. Alarm system for intrusion detection
. Full motion video camera
. Constant supervision of entrance and data center
. The card and access code required to enter the data center
. Database of individuals with access control
. Man Trap Security - only authorized personnel can enter the data center
. 24/7/365 monitoring
. 6 APC NetBotz surveillance cameras
. Locked racks for every server
. Registration of equipment serial numbers
. Emergency access for all customers with priority
. Electronic record of every access
. Overseeing the environment to prevent damage to equipment
Fire-extinguishing System
VeratNet's data center is protected by fire systems in two zones. System FM200 fire extinguishers without the use of water allow the best possible fire protection.
. The system for fire detection in two areas
. Photoelectric smoke detectors for early warning
. Warning heat systems as a secondary system of protection
. FM 200 fire alarm system - based on a harmless gas
. Fire extinguishing systems with double dry tube
. Water - outside the critical equipment area
. The sprinklers do not damage the equipment
. Alarm system without the possibility of error - prevents false activation or a mistake
. Activation of the pre-action, specific to a particular zone
. Smoke tube in accordance with regulations